HORIZONTAL OR VERTICAL · RETROFIT OR NEW BUILD

TWO ORIENTATIONS.
ONE DROP-IN
FOOTPRINT.

The Roto-Jet® VSR Hyper-Drive™ installs horizontally or vertically and is dimensionally matched to common integrally geared centrifugal footprints. It replaces an existing pump with minimal piping and foundation work or specifies into a new build from day one.

125 GPM MAX FLOW
4,000 FT MAX HEAD
5,443 RPM
SINGLE STAGE
Roto-Jet VSR Horizontal Pump
HORIZONTAL
Roto-Jet VSR Vertical Pump
VERTICAL
ONE PLATFORM · DROP-IN RETROFIT · NEW OE SPECIFICATION · SAME HYDRAULICS, SAME DRIVE, EITHER WAY
SEE HOW IT FITS
 Fits what you already have

Pick the orientation the plant room allows.

Identical hydraulics and an identical integrated drive in both arrangements. The orientation is a footprint decision, not a performance trade-off.

Orientation — horizontal
Skid-mounted, low profile

A compact horizontal package for skid and baseplate installations, sized to drop into existing pump bays without reworking piping runs.

Orientation — vertical
Minimal floor space

A base-mounted vertical arrangement that reclaims plan area where floor space is the constraint. Same hydraulics, same drive.

Application — retrofit
Replace what is already installed

Dimensionally matched to common integrally geared centrifugal footprints, so the existing unit comes out and the VSR Hyper-Drive goes in. Minimal piping changes, minimal foundation work, and no new bay layout.

Application — new build
Specify it from day one

A single-stage, high-head platform with variable-speed control and standard motor components. Specified as new OE equipment with the drive already integrated and nothing to align in the field.

• Integrated direct drive

The best part
is what’s missing.

The drive is built into the pump. Everything that used to sit between the motor and the hydraulics is gone. This allows for a smaller overall footprint than the traditional arrangement that it replaces.

  • NO EXTERNAL GEARBOX
  • NO FLEXIBLE COUPLINGS
  • NO FIELD ALIGNMENT
  • FEWER MECHANICAL COMPONENTS
  • REDUCED INSTALLATION FOOTPRINT
 Performance capabilities

The numbers.

ROTO-JET VSR HYPER-DRIVE US METRIC
MAXIMUM FLOW 125 gpm 28 m³/hr
MAXIMUM HEAD 4,000 ft 1,200 m
MAXIMUM SUCTION PRESSURE 50–200 psi 3.5–14 bar
MAXIMUM SUCTION TEMPERATURE 180° F 82° C
MAXIMUM SUCTION TEMPERATURE WITH FLUSH 250° F 121° C
MAXIMUM SPEED 5,443 rpm  

Values represent platform capability, not a single operating point. The certified performance curve governs selection for any specific application.

Standard induction motor

A squirrel-cage design with no brushes or commutators: components any plant maintenance team already knows, in worldwide 50/60 Hz configurations.

Separately mounted VFD

The drive is not integral to the pump. Trillium can supply it as part of a complete package, or you source it to match existing site standards.

Variable-speed control

Soft start and stop, reduced inrush current, and accurate speed regulation for applications that need consistent flow or pressure as demand shifts.

NO FORM REQUIRED

GET THE FULL BROCHURE

Six pages: configurations, direct-drive advantages, the VFD and motor story, exploded component view, and the full performance table.

DOWNLOAD PDF

Send us your duty point.

Tell us the flow, the head, and the footprint you are working inside. An application engineer will come back with a configuration and a certified curve.