86 Series Pilot Operated Pressure Relief Valve

June 10, 2020|

The Sarasin-RSBD 86 SERIES FULL NOZZLE design is based on our experience in NUCLEAR applications. It has been developed to protect drum, superheater and to comply with local regulation where isolated steam from atmosphere and remote sensing line are mandatory statement.

The Sarasin-RSBD 86 SERIES Pilot Operated Pressure Relief Valve has been developed to high temperature steam requirements. This new design and material is based on our extensive experience in nuclear applications. The DMS technology is the same as than currently used by SEBIM in NUCLEAR power plant. The design of the valve seal is performed without any elastomer. The main valve dome and DMS pilot sealing is insured by metallic bellows. This feature allows the Pilot Operated Pressure Relief Valve to keep a constant steam flow through the DMS pilot and the main valve without any impact on valve performance. "Hang-up" of guiding surfaces associated with comparable valves is eliminated with a unique anti-sizing feature. the first Pilot Operated Pressure Relief Valve in the world to offer this technology to prevent such kind of failure.

71 Series Pilot Operated Pressure Relief Valve

June 10, 2020|

The Sarasin-RSBD 71 SERIES design has been developed for customer who want to protect piping or vessel against thermal expansion overpressure in gas service, keeping operating pressure close to the set pressure.

The Sarasin-RSBD 71 SERIES design is based on thermal expansion spring-loaded body design (9 SERIES) The Sarasin-RSBD 71 SERIES are an engineered custom-made design that has been industrialized and offer FULL NOZZLE Pilot Operated Pressure Relief Valve in Industrial Gas Service:
  • FULL NOZZLE version is better to insure body chemical protection
  • In case of upgraded process (higher backpressure / higher operating pressure) customer can simply go from Spring Loaded to Pilot Operated version keeping the same center-to-face dimension.
  • FULL NOZZLE version are integral wetted components which offer the advantage of removal for maintenance and replacement.

78 Series Pilot Operated Pressure Relief Valve

June 9, 2020|

The Sarasin-RSBD 78 SERIES SEMI NOZZLE design has been developed in compliance with API STD 526 to protect against overpressure, withstanding the most stringant criteria in term of operating pressure and back pressure

The Sarasin-RSBD 78 SERIES Pilot Operated Pressure Relief Valve is an autonomous unit and therefore it does not need an external source of power for it to operate. Used mostly in the oil and gas industry this pressure relief valve can be used in vapour, gas, liquid or steam applications. Precision machined internal components and high integrity soft goods mean that the Sarasin-RSBD 78 SERIES Pilot Operated Pressure Relief Valves are designed to provide excellent operational performance and repeatability.

DSM 3000 Small size reactor safety valve

November 15, 2019|

The SEBIM POSV type DSM 3000 is our most compact design from within the SEBIM safety valve range and offers versatility, robust design and proven reliability.

This model is suitable for all types of nuclear reactors which require high and low overpressure protection on liquid, steam, gas and steam/water mix applications with small capacity and high speed pressure transient. The SEBIM POSV type DSM 3000 was developed especially for submarines, scaled down reactors, experimental reactors, PWR, PHWR or HTGR. The piloting system, which is integrated into the main valve, operates under steam, gas, liquid or two phase flow duties.

GVG 3000 Main steam safety valve

November 4, 2019|

The SEBIM POSV type GVG 3000 is designed for overpressure protection of the Nuclear Steam Supply System (NSSS) in all designs of nuclear reactor.

The SEBIM POSV GVG series was developed for overpressure protection of the Steam Generator or the Main Steam Lines of all designs of nuclear reactor. The GVG series is the tubeless design of the previous SGSV series and uses some tubing interface with piloting systems in operation since the 1990s.

PRG 3000 Primary coolant safety valve

November 4, 2019|

The SEBIM POSV PRG 3000 is designed for overpressure protection in primary circuits of all designs of nuclear reactors, including third and fourth generations reactors.

The SEBIM POSV type PRG 3000 series is qualified for overpressure protection of the primary circuit of the third generation Pressurised Water Reactors (PWRs) (including EPR, VVER 1000 & 1200 etc.). Our PRG 3000 design is currently in operation throughout several primary loop second generation reactors (PWR, PHWR, VVER, and RBMK).

74LP, 74VP & 78LP Series Pilot Operated Pressure Relief Valve

November 4, 2019|

The Sarasin-RSBD 74 Series Pilot Operated Pressure Relief Valve provides the capability for the protection of storage vessels, tanks and piping systems under low pressure and vacuum conditions.

The Sarasin-RSBD 74VP, 74LP & 78LP Series Pilot Operated Pressure Relief Valves are autonomous units and therefore they do not need an external source of power to operate. Pilot operated pressure relief valves are most effectively used within liquefied natural gas and floating liquefied natural gas industries. The valves are also effective in processes involving petrochemical refinement and the power industry. The Sarasin-RSBD pressure relief valves are designed to provide excellent operational performance and repeatability by their use of precision machined internal components and high integrity soft goods.

Stareco (76E Series) Pilot Operated Pressure Relief Valve

November 4, 2019|

The Stareco Pilot Operated Pressure Relief Valve is designed to provide overpressure protection for the challenging Section I economizer application.

The Stareco Pilot Operated Pressure Relief Valve is designed to meet the rigorous process conditions which are mandated by boiler economizers. The pressure relief valves are designed to provide high integrity performance and repeatability in the power industry, particularly at high pressure and high temperatures. Their use of “Thermoglide” components eliminates any problems associated with seizing or galling of internal surfaces and guarantees excellent overpressure and blowdown characteristics.

76 Series Pilot Operated Pressure Relief Valve

November 4, 2019|

The Sarasin-RSBD 76 SERIES FULL NOZZLE design has been developed for customer who want to protect vessel against overpressure in cryogenic condition or insure body chemical protection, keeping the highest tighness requirements.

The Sarasin-RSBD 76 SERIES design is based on API STD 526 spring-loaded body design (P SERIES) including limited acceptable back pressure value. Therefore, the center-to-face dimensions and inlet/outlet rating meet API STD 526 for spring-loaded valves. In the API STD 520 Part I, the selection of the nozzle type is only available for Spring-Loaded PRV, not Pilot Operated PRV which are designed with semi-nozzle as a standard design.

Starvalve (RS type) Changeover Valve

November 1, 2019|

The Sarasin-RSBD Starvalve series of Changeover Valves provides a safe and efficient method of switching from an active to a standby Pressure Relief Valve.

The Starvalve Changeover Valve provides easy maintenance for a Pressure Relief Valve without having a process shutdown. It is designed to meet industry standard low pressure drop requirements and features a tested packing design with minimal leak points reducing fugitive emissions. Due to the changeover valve's design, no seat lapping is required for maintenance meaning there are minimal spare parts and a reduced cost of ownership. It reduces the risk of a pressure relief valve chattering from excessive pressure drop through traditional shuttle type changeover valves. The Starvalve is a rotor type changeover valve which maintains a pressure drop of pressure below 3% through its body. This changeover valve is designed for use in refineries within the petrochemical and cryogenic industries.